St. Lucie Mobile Village

Location
Indiantown, Florida
Serves
750
Source
Groundwater
Data
2024

Overview

St. Lucie Mobile Village is a public drinking-water system serving about 750 people in Martin County, Florida.

Lead was detected in this system’s water. EPA states its health effects: in infants and children: delays in physical or mental development; in adults: kidney problems and high blood pressure.

Gross Alpha emitters were detected in this system’s water. EPA states their health effects: may increase the risk of cancer.

TTHM (Total Trihalomethanes) was detected in this system’s water. EPA states its health effects: may increase the risk of cancer; liver, kidney, or central nervous system effects.

EPA’s health goal for Lead and Gross Alpha emitters is zero. There is no amount of them it considers safe to drink.

PFOS was detected, one of the forever chemicals that do not break down in the body or in the environment. EPA states the health effects: effects on cholesterol, the liver, the immune system, and thyroid; may increase the risk of certain cancers.

It serves Indiantown.

It uses groundwater as its source.

Contaminants Detected

Not detected, or not looked for 97

PFAS · EPA UCMR5 monitoring

These were genuinely sampled, because EPA required it. Of 29 PFAS “forever chemicals” tested under the UCMR5 program, 1 were detected (shown above) and 28 were not:

11Cl-PF3OUdS, 4:2 FTS, 6:2 FTS, 8:2 FTS, 9Cl-PF3ONS, ADONA, HFPO-DA, NEtFOSAA, NFDHA, NMeFOSAA, PFBA, PFBS, PFDA, PFDoA, PFEESA, PFHpA, PFHpS, PFHxA, PFHxS, PFMBA, PFMPA, PFNA, PFOA, PFPeA, PFPeS, PFTA, PFTrDA, PFUnA

Regulated contaminants · no result on record

Federally regulated contaminants with no reading on record for this system. A missing reading can mean the sample came back clean, or that nobody was required to take one. The published data does not say which, and smaller systems monitor many of these only once every few years:

1,1,1-Trichloroethane, 1,1,2-Trichloroethane, 1,1-Dichloroethylene, 1,2,4-Trichlorobenzene, 1,2-Dichloroethane, 1,2-Dichloropropane, 2,4,5-TP (Silvex), 2,4-D, Alachlor, Antimony, Arsenic, Asbestos, Atrazine, Benzene, Benzo(a)pyrene, Beryllium, Beta particle & photon emitters, Bromate, Cadmium, Carbofuran, Carbon tetrachloride, Chlordane, Chlorite, Chlorobenzene (monochlorobenzene), Chromium (total), Combined radium (Ra-226 & Ra-228), Cyanide, Dalapon, Di(2-ethylhexyl)adipate, Di(2-ethylhexyl)phthalate, Dibromochloropropane (DBCP), Dichloromethane (methylene chloride), Dinoseb, Dioxin (2,3,7,8-TCDD), Diquat, Endothall, Endrin, Ethylbenzene, Ethylene dibromide (EDB), Fluoride, Glyphosate, Heptachlor, Heptachlor epoxide, Hexachlorobenzene, Hexachlorocyclopentadiene, Lindane, Mercury (inorganic), Methoxychlor, Nitrate, Nitrite, Oxamyl (Vydate), Pentachlorophenol, Picloram, Polychlorinated biphenyls (PCBs), Selenium, Simazine, Styrene, Tetrachloroethylene, Thallium, Toluene, Toxaphene, Trichloroethylene, Uranium, Vinyl chloride, Xylenes (total), cis-1,2-Dichloroethylene, o-Dichlorobenzene, p-Dichlorobenzene, trans-1,2-Dichloroethylene

How this plant treats the water

FDEP records 2 treatment processes here, under 2 headings.

disinfectionhypochlorination
organics removalreverse osmosis

From FDEP’s treatment facility report, 2023. It lists what each plant is equipped to do, which is not the same as what any single process removes on a given day, and treatment happens before the water reaches your service line or your own plumbing.

What happened when this system broke the rules

Measurements are only half the record. These are St. Lucie Mobile Village’s violations of the drinking-water rules as recorded by EPA, 2025, and what followed them.

1health-based violationLimit or treatment failures, not paperwork.
1still openNo return-to-compliance date on record.
1enforcement action0 informal, 1 formal.
0carried a penaltyNo fine was ever assessed.

A system in violation keeps operating, because cutting off a community’s water is not a remedy anyone wants. That is the point worth understanding: the enforcement record and the water are two different things, and only one of them appears in the annual report you are mailed. What that looks like statewide →

The Solution

01

Get your water tested

We measure what is actually coming out of your taps - hardness, iron, pH, TDS, PFAS, and whatever your own plumbing adds - the things a utility report can never show.

02

See your real results

We walk you through exactly what is there and what it affects: your skin, your pipes, your appliances, and the taste. Measured at your tap, not at the plant.

03

Get recommendations

Based on your results, we recommend the treatment that fits your water - a softener, reverse osmosis, or whole-home filtration - and nothing you do not need.

Know when your water changes

We will email you when new readings, violations or health goals land for your system.

Or schedule a water consultation.

Data Sources

EPA SDWISSystem identity, source, population, ZIP mapping · PWS FL4431379ret. 2026
EPA UCMR 5PFAS measured occurrence (2023–25)ret. 2026
2024 CCRRegulated contaminants - the utility’s own reportret. 2026
FDEPFlorida drinking-water chemical monitoring - additional regulated analytesret. 2026
EPA SDWISViolation and enforcement history for PWS FL4431379ret. 2026
CA OEHHACalifornia public health goals, the health-based benchmark where one is publishedret. 2026
FWROur own benchmarks, only where no government body has published one, each citing the official source it is built onret. 2026

These figures describe the water your utility delivers, drawn from public federal and state records - not our own lab samples, and not what your home’s plumbing adds after the water arrives. Informational; not a substitute for testing your own tap.

Get your home’s actual numbersSchedule a consultation